Beckwith Electronics

Hamburg, Illinois 62045
(618) 232-1139

(618) 232-1172 fax

Contact Us

Power Dynamics, Inc.

    Features
  • Both common mode and normal mode are high noise rejection
  • Low leakage current: 1mA max
  • Screw output terminals M-4
    Applications
  • Digital electronic equipment, measuring control equipment, small electronic equipment and peripherals, etc.
PE05PS
PE10PS
PE15PS
PE20PS

Approvals:

(VDE submitted)

Specifications
Model No. PE05PS PE10PS PE15PS PE20PS
Rated Voltage 250V AC 250V AC 250V AC 250V AC
Rated Current 5A 10A 15A 20A
Leakage Current 1mA
250V, 60Hz
1mA
250V, 60Hz
1mA
250V, 60Hz
1mA
250V, 60Hz
Test
Voltage
Line to Line 1450V DC 1450V DC 1450V DC 1450V DC
Line to Ground 2250V DC 2250V DC 2250V DC 2250V DC
Insulation Resistance 6000M ohms MIN 6000M ohms MIN 6000M ohms MIN 6000M ohms MIN
Direct Current
Resistance
0.3 ohm MAX 0.15 ohm MAX 0.1 ohm MAX 0.05 ohm MAX
Temperature Rise 35°C MAX 35°C MAX 35°C MAX 35°C MAX
Operating Temperature -25°C to
+85°C
-25°C to
+85°C
-25°C to
+85°C
-25°C to
+85°C
Attenuation
Normal Mode
30db MIN
0.32 - 43 MHz 0.28 - 28 MHz 0.35 - 40 MHz 0.47 - 40 MHz
Common Mode
30db MIN
0.32 - 40 MHz 0.20 - 25 MHz 0.25 - 40 MHz 0.90 - 40 MHz

Circuit

Part No. L(mH) x 2 Cx (µF) x 2 Cy (pF) x 2 R (ohm)
PE05PS 5 0.1 3300 10M
PE10PS 3 0.1 3300 10M
PE15PS 2 0.1 3300 10M
PE20PS 0.9 0.1 3300 10M

Drawings

Attenuation in 50 ohm-50 ohm circuit according CISPR

Specifications subject to change without notice. (Metric dimensions are shown in parentheses.)