Beckwith Electronics

Hamburg, Illinois 62045
(618) 232-1139

(618) 232-1172 fax

Contact Us

Power Dynamics, Inc.

    Features
  • General purpose filter with IEC Connector providing effective equipment protection of line-to-ground noise up to 10 amp., 250 VAC
  • Low cost
  • Compact design
  • Low leakage current: less than 0.5mA max
  • .250" Quick Connect terminals
    Applications
  • Digital electronic equipment, measuring and control equipment, small electronic equipment and pheripherals, ect.
PB01F
PB03F
PB06F
PB10F

Approvals:

Specifications
Model No. PB01F PB03F PB06F PB10F
Rated Voltage 250V AC 250V AC 250V AC 250V AC
Rated Current 1A 3A 6A 10A
Leakage Current 0.5mA MAX
250V, 60Hz
0.5mA MAX
250V, 60Hz
0.5mA MAX
250V, 60Hz
0.5mA MAX
250V, 60Hz
Test
Voltage
Line to Line 1450V DC 1450V DC 1450V DC 1450V DC
Line to Ground 2250V DC 2250V DC 2250V DC 2250V DC
Insulation Resistance 6000M ohms
MIN 250V DC
6000M ohms
MIN 250V DC
6000M ohms
MIN 250V DC
6000M ohms
MIN 250V DC
Direct Current
Resistance
0.5 ohm MAX 0.2 ohm MAX 0.15 ohm MAX 0.1 ohm MAX
Temperature Rise 30°C MAX 30°C MAX 30°C MAX 30°C MAX
Operating Temperature -25°C to
+85°C
-25°C to
+85°C
-25°C to
+85°C
-25°C to
+85°C
Attenuation
Normal Mode
25db MIN
0.60 - 45 MHz 0.80 - 50 MHz 1.00 - 50 MHz 1.00 - 50 MHz
Common Mode
25db MIN
0.10 - 40 MHz 0.20 - 40 MHz 0.50 - 50 MHz 0.70 - 50 MHz

Circuit

Part No. L(mH) x 2 Cx (µF) Cy (pF) x 2
PB01F 3.7 0.1 3300
PB03F 1.8 0.1 3300
PB06F 0.7 0.1 3300
PB10F 0.3 0.1 3300

Drawings


Front of Panel

Back of Panel

Attenuation in 50 ohm-50 ohm circuit according CISPR
PB01F (1 AMP)

PB03F (3 AMP)

PB06F (6 AMP)

PB10F (10 AMP)

Specifications subject to change without notice. Dimensions in inches. (Metric dimensions are shown in parentheses.)